Homogenizer equipment operation requirements

Jun 28, 2019

(1) You must check the following contents before starting the machine.

1. Confirm that the inlet and outlet of the homogenizer are fully open, the cooling water of the plunger shaft has been opened, the liquid in the feed has been stored, and the lubricant has been checked to the specified level.


(2) boot

1. Turn on the power, the homogenizer starts working, slowly open the pressure chamber exhaust valve to discharge the gas in the pressure chamber, close the exhaust valve, slowly turn the pressure handle, and the pressure indicator needle rises to 10MP, stop adding Pressure, observe whether it is normal, and the pressure is controlled between 10MP and 15MP.

2. Always check whether the pressure indication is at the specified position, check whether the cooling water is normal, touch the body with your hand, and feel the temperature of the body is normal. If you find that the temperature of the body rises too fast or you feel hot, stop it immediately.


(3) Shutdown

1. Turn off the power and water.

2. Clean the machine.